Skip to main content

MasterLine 8 High Insulation

Technical information

Performance

Energy

Thermal insulation - Uf
1.7 W/m²K
Thermal insulation - Uw
1.0 W/m²K
Uw Dependencies
Frame-vent: Ug 0.6W/m²K, warm edge spacer,@1.23x1.48m (104mm sight line), 36mm glass

Comfort

Air tightness
Class 4 (600Pa)
Water tightness
Class E900 (900Pa)
Wind load resistance
Class C5 (2000Pa)
Acoustics - Rw(C;Ctr)
TuTi: 46(-1;-3) dB DC: 44(-2;-4) dB
Opening & closing resistance
Class 3

Safety

Burglar resistance
RC2 - RC3
Impact resistance
I5 - E5
* Note: Performances and properties may be different depending on the profile combinations

Properties

Sightlines

Min. frame width (inward opening)
53 mm
Min. vent width (inward opening)
37 mm
Min. frame-vent width (inward opening)
97 mm
Min. frame width (outward opening)
20 mm
Min. vent width (outward opening)
96 mm
Min. frame-vent width (outward opening)
116 mm
Depth frame
77 mm
Depth Vent
87 mm
Depth frame-vent
87 mm

Glazing

Rebate height
27 mm
Glazing method
Dry glazing - Siliconized glazing - Internal glazing - External glazing - Glazing bead - Structural Glued Glazing
Min. glass thickness - vent
13 mm
Max. glass thickness - vent
68 mm