Skip to main content

ConceptSystem 77 Smoke & Heat Evacuation

Technical information

Performance

Energy

Thermal insulation - Uf
1.9 W/m²K
Thermal insulation - Uw
1.3 W/m²K
Uw Dependencies
Frame-vent HI: Ug 1.0W/m²K, warm edge spacer,@1.23x1.48m (102mm sight line), 36mm glass

Comfort

Air tightness
Class 4 (600Pa)
Water tightness
Class 9A (600Pa)
Wind load resistance
Class C5 (2000Pa)
Opening & closing resistance
Class 3
* Note: Performances and properties may be different depending on the profile combinations

Properties

Max. dimensions & weight

Min. height of vent
600 mm
Max. height of vent
2800 mm
Min. width of vent
450 mm
Max. width of vent
1700 mm

Sightlines

Min. frame-vent width (inward opening)
115 mm
Min. vent-vent width (inward opening)
144 mm
Min. frame width (outward opening)
17.5 mm
Min. width T-profile
76 mm
Depth frame
68 mm
Depth Vent
77 mm
Depth frame-vent
77 mm

Glazing

Rebate height
25 mm
Glazing method
Dry glazing - Siliconized glazing - Internal glazing - Glazing bead
Min. glass thickness - frame/element
4 mm
Max. glass thickness - frame/element
52 mm
Min. glass thickness - vent
4 mm
Max. glass thickness - vent
63 mm