Skip to main content

ConceptWall 50 Mullion Transom

Technical information

Performance

Energy

Thermal insulation - Uf
0.8 W/m²K

Comfort

Air tightness
AE1200 (1200Pa)
Water tightness
RE1200 (1200Pa)
Wind load resistance
2000 Pa
Acoustics - Rw(C;Ctr)
47(-2;-5) dB

Safety

Burglar resistance
RC2 - RC3
* Note: Performances and properties may be different depending on the profile combinations

Properties

Max. dimensions & weight

Min. intertia mullion - Ix
14 cm4
Max. intertia transom - Ix
612 cm4
Min. intertia transom - Iy (glass load)
8 cm4
Max. intertia transom - Iy (glass load)
59 cm4

Sightlines

Min. visible width (interior view)
50 mm
Min. visible width (exterior view)
50 mm
Min. depth mullion
41.5 mm
Max. depth mullion
300 mm
Min. depth transom
5 mm

Glazing

Glazing method
Dry glazing - External glazing - Pressure plate glazing - Structural Glued Glazing - Structural clamped glazing - Structural Glued Stepped Glazing